Bante903P
Portable pH/ORP/DO Meter


pH Mode:
• High accuracy portable multiparameter water quality meter is equipped with a large backlit
LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 11 parameters, including the calibration points, resolutions, stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly.
Specification:
| Model | Bante903P |
| pH | |
| Range | -2.000~20.000pH |
| Accuracy | ±0.002pH |
| Resolution | 0.1, 0.01, 0.001pH |
| Calibration Points | 1 to 5 points, USA, NIST, DIN Standards |
| Temperature Compensation | 0~100°C, 32~212°F, Manual or Automatic |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1, 1mV |
| Calibration Points | 1 point (Only for Relative mV mode) |
| Calibration Range | ±200mV |
| Dissolved Oxygen | |
| Range | 0.00~20.00mg/L (or ppm) |
| Accuracy | ±0.2mg/L |
| Resolution | 0.01mg/L |
| Calibration Points | 1 or 2 points |
| Temperature Compensation | 0~50°C, 32~122°F |
| Pressure Correction | 60.0~112.5kPa, 450~850mmHg |
| Salinity Correction | 0~50g/L |
| % Saturation of Oxygen | |
| Range | 0.0~200.0% |
| Accuracy | ±2.0% |
| Resolution | 0.10% |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Points | 1 point |
| Calibration Range | Measured value ±10°C |
| Others | |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC, 6-pin Mini Plug |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
Order Information:
| Order Code | Accessories |
| Bante903P-CN | E201-BNC pH Electrode |
| DO100 Dissolved Oxygen Probe (Made in US) | |
| TP-10K Temperature Probe | |
| pH Buffer Solutions (pH4.01/7.00/10.01) | |
| DO Filling Solution | |
| DO Cap Membrane | |
| AA Batteries | |
| Carrying Case | |
| Bante903P-UK | P11 pH Electrode (Made in UK) |
| DO100 Dissolved Oxygen Probe (Made in US) | |
| TP-10K Temperature Probe | |
| pH Buffer Solutions (pH4.01/7.00/10.01) | |
| DO Filling Solution | |
| DO Cap Membrane | |
| AA Batteries | |
|
Carrying Case |